Barrier Type Terminal Block (307 Sản phẩm)

Multiservice Access Multiplexer (2U) iSAP2000

The iSAP2000 is a 2U 19” 6 slots rack type E1 Time Division Multiplexer for fractional E1 network across, which is designed for nonstop operation.

  • Supports MAX. 96xE1 with full cross-connect, Supports DS0 cross-connect
  • Supports 16 channel Main E1 LTU card
  • Supports E1 time slot broadcast function
  • Modular design for Voice I/O card, the voice I/O card has two sub-module, each sub-module supports 4-port FXO/FXS
  • All modules and cards support hot-swapping
  • DCE card types included N*64K, RS232(Sync/Async), G703-64K,
  • ET100, ET100R, E&M, FXO, FXS, FOM01, FOM02...etc.
  • Supports Console, Telnet, SNMP and GUI management
  • Available types of power built-in : AC+AC, AC+DC, DC+DC
  • Modular design, 2U 19”, 6-slot for I/O cards

E1/4x E1 over Ethernet with Web Management

IPM-E1/4E1 is designed as a multi-service access platform for PDH over IP applications. E1 frames can be mapped/de-mapped into/ from IP packets. An adaptive clock recovery method for Ingress PDH (PSN->TDM) clock generation is implemented to support E1 (ITU-T G.823) Jitter performance.

  • Supports Web Management
  • Supports IETF RFC4553 Structure-Agnostic TDM over Packet (SAToP), Metro Ethernet Forum MEF8
  • Use Raw Encapsulation method for PDH payload over Ethernet packet
  • Supports Circuit Emulation Service over Ethernet networks
  • Comply with IETF draft standard for CESoPSN and SAToP; Metro Ethernet Forum MEF8 IA
  • Supports both Point-to-Point and Point-to-Multipoint operation
  • Supports Adaptive Clock recovery block for Ingress PDH (PSN -> TDM) clock generation. Recovered clock jitter is compliant to ITU-T G.823 (E1 Jitter Control)
  • Configurable jitter buffer depth to compensate PDV (Packet Delay Variation) with the flexible setting of 11ms, 23ms, 40ms, 75 ms
  • Lost packets processing / compensation via PW (Pseudo Wire) control field Sequence Number
  • Provide Subscriber side Data traffic bandwidth control to guarantee enough TDM payload bandwidth
  • PDH LOS detection triggered PW L field or payload AIS generation at Egress direction (TDM->PSN)
  • Configurable IEEE 802.3 DA/SA assignment
  • LED alarm display for E1 Power failure status
  • E1 NRZ Serial Interface with LOS/AIS detection

8/16x E1 over Ethernet IPM-8E1, IPM-16E1

IPM-8E1 & IPM-16E1 is designed as a multi-service access platform for PDH over IP applications. E1 frames can be mapped/de-mapped into/from IP packets.

  • Supports Web Management
  • Supports IETF RFC4553 Structure-Agnostic TDM over Packet (SAToP), Metro Ethernet Forum MEF8
  • 8 /16 x E1 NRZ Serial Interface with LOS/AIS detection
  • Use Raw Encapsulation method for PDH payload over IP packet
  • Supports Circuit Emulation Service over IPE
  • Comply with IETF draft standard for CESoPSN and SAToP; Metro Ethernet Forum MEF8 IA
  • Supports both Point-to-Point and Point-to-Multipoint operation
  • Configurable IEEE 802.3 DA/SA assignment
  • Supports 8/16 independent Adaptive Clock recovery block for Ingress PDH (PSN->TDM) clock generation. Recovered clock jitter is compliant with ITU-T G.823 (E1 Jitter Control)v
  • Independent configurable jitter buffer depth to compensate up to 250ms of Packet Delay Variation
  • Lost packets processing / compensation via PW (Pseudo Wire) control field Sequence Number
  • PDH LOS detection triggered PW L field or payload AIS generation at Egress direction (TDM->PSN)
  • LED alarm display for E1 Power failure status

iAccess™ Multi-Service Platform - FRM220 Series

The FRM220 series is a multi-service platform chassis, which provides a reliable solution of high density media converter modules for applications such as telecom operator, enterprise, long haul transmission and factory automation.

  • Interface cards are hot swappable
  • Supports AC/DC power modules hot swappable and power redundancy (CH20 & CH08)
  • Supports fixed type AC/DC power built-in and power redundancy (CH04A)
  • Two alarm relay contacts for critical events warnings (CH20/CH08)
  • Chassis backplane consists of passive components (CH20/CH08)
  • Fanless (CH02, CH02M-2, CH01, CH01M )
  • Cooling Fan (CH20, CH08, CH04A, CH02M, CH02/SMT, CH02/NMC )
  • Supports DB9 console port for local management (CH02M, CH02M-2, CH01M )
  • Telnet, Web, Console, SNMP management via NMC Card (CH20, CH08, CH04A, CH02/SMT, CH02/NMC )

High-performance industrial grade wireless router ICR-W403

The ICR-W403 is a high-performance industrial grade wireless router. It combines IEEE 802.11b/g/n/ac WLAN and 4G LTE cellular technologies to provide flexible wireless network connectivity for industrial applications.

  • IEEE 802.11 ac/b/g/n, multiple SSID, captive portal for WiFi hotspot
  • Web, CLI ,SNMP, TR069, SMS for management and configuration
  • Events triggered by pre-defined, and notification sent by SMS, SNMP trap, or e-mail
  • Supports USB for log storage
  • EN-60950-1, CE, FCC, Rail Traffic EN50121-4 certified
  • Heavy industrial grade EMS, EMI, EN61000-6-2, EN61000-6-4 certified
  • Rugged metal, IP30 protection & Fanless design

Rish Master 3440 - Class 0.2s

RISH Master 3440 is a class 0.2S as per IEC 62053.-22. It measures more then 46 important electrical parameters of 3phase/1phase system along with THD & individual harmonics upto 31st. It can communicate through ethernet /RS485 with external device, and it also have Pulse output and 4-20mA analog output.

  • Input : 57 .7…346 VLN/ 100…600VLL (Programmable) - 45…65 Hz 1A or 5A (Programmable)
  • Auxiliary: 60V ...300V AC/DC or 12...60V AC/DC
  • Display :  4 Digit 3 Line for LED V ersion
  • Accuracy : Class 0.2 & Class 0.2S (on request)
  • V ersions : LED – Rish Master 3440
  • Measures: V , A, Hz, KW, KV Ar, KV A, PF, Phase Angle, KWH, KV ArH, KV AH, Neutral Current, THD, Demand, Run Hour, ON Hour , No. of Interruptions
  • Protection: IP54 from Front Side
  • Output: RS485 Modbus + 2x Relay Output or RS485 Modbus + 1x Relay + 2x Analog Outputs or Ethernet Modbus (TCP /IP) - RJ45
  • Size: 96 x 96 x 80 mm

Rish Master 3440i - Class 0.2s

RISH Master 3440i is a class 0.2S as per IEC 62053-22. It measures more than 46 important electrical parameters in 3Ph3/4W & 1PH2W system along with THD & individual harmonics upto 31st. RISH Master 3440iDL has 8MB flash for datalogging

  • Input : 57 .7…346 VLN/ 100…600VLL (Programmable) - 45…65 Hz 1A or 5A (Programmable)
  • Auxiliary: 60V ...300V AC/DC or 12...60V AC/DC
  • Display :  4 Digit 3 Line for LED V ersion
  • Accuracy : Class 0.2 & Class 0.2S (on request)
  • LCD – Rish Master 3440i / 3480 (T ouch Screen)
  • Measures: V , A, Hz, KW, KV Ar, KV A, PF, Phase Angle, KWH, KV ArH, KV AH, Neutral Current, THD, Demand, Run Hour, ON Hour , No. of Interruptions
  • Protection: IP54 from Front Side
  • Output: RS485 Modbus + 2x Relay Output or RS485 Modbus + 1x Relay + 2x Analog Outputs or Ethernet Modbus (TCP /IP) - RJ45
  • Size: 96 x 96 x 80 mm

RISH LM1360/ LM 1350 Series

RISH LM1360 measures important electrical parameters in 3P4W,3P3W & 1P2W like Active / Reactive / Apparent energy, power and all basic parameter.The instrument has two optional outputs. It can be configured as pulse output for energy measurement, limit output , timer function and RTC relay.

  • Input : 57 .7…346.42 V LN/ 100…600V LL (Programmable)-45…66 Hz ; 1A or 5A(Programmable) ; 100mA in case of Plug & play CT option
  • Auxiliary: 100V ...550V AC/DC or 12-60V AC/DC
  • Accuracy: Class 0.2S; Class 1 (for Plug and play CT option)
  • Display : 4 Line 4 Digit LCD display +9 digit separate energy counter + Load analog graph
  • Measures: LM 1360 – V , A, Hz, KW, KV Ar, KV A, PF, Phase Angle, KWh, KV Arh, KV Ah, Neutral Current, Harmonics (31st), THD, Demand, Run Hour , ON Hour , No. Of Interruptions, old parameters
  • Output : RS485 Modbus + 2 x Pulse Output or Ethernet, (Modbus T CP /IP) or Ethernet (Modbus T CP /IP) + Data logging + RTC RS485 Modbus + 2x Pulse ; Output + Data logging + USB + RTC or GSM Data Logger (All plug and play modules)
  • Protection : IP50 from Front Side
  • Size (H x W x D) : 96 x 96 x 70 mm

Temperature Controller - RE56

The controller is designed for the temperature control. Controller works directly with the resistance sensors or thermocouple sensors .The controller is equipped with outputs that allows for control and alert signalization. Control output can be programmed for PID or ON/OFF algorithm.

  • Universal Measuring Input: (RTD & TC)
  • Digital Input Filter - Useful for noise suppression
  • Control Type: On / OFF or PID Mode
  • Operation Modes: Automatic or Manual
  • Timer Function
  • Heating / Cooling control

Temperature Controller - RE57, RE77 & RE96

The controller is desgined for the temperature control. Controller works directly with the resistance sensors or thermoelectric sensors or analog input .The controller is equipped with outputs that allows for control and alert signalization. Control output can be programmed for PID or ON/OFF algorithm.

  • Universal Measuring Input
  • Digital Input Filter - Timer settable from 0 ... 999.9 seconds
  • Control Type : PID and ON / OFF
  • Onsite Mode Selection: Auto / Manual
  • Timer Function: with 5 functional selection
  • Onsite programmability -Heating / cooling
  • Output on Failure function

RISH Relay - PHR

RISH Relay -PHR monitors AC voltage of a system/equipment and protects it from phase failure issues. Suits applications such as  Control close loop operations, Conveyor system, motor protection from faults like incorrect phase sequence, unbalance in phase or loss of phase.

  • True RMS measurement
  • Self Powered
  • Instrument automatically clears (resets) itself as soon asfault condition is recovered
  • Compliance to International Safety standard IEC 61010-1-2010
  • LED indication for Unbalance, Phase Fail condition and incorrect Phase Sequence condition
  • Well suited for 3PH 3W and 3PH 4W applications

RISH Relay - VR

RISH Relay - VR monitors AC voltage of a system/equipment and protects it from overvoltage, undervoltage and phase failure issues. As well as it indicates the occurrence of faults with help of LED indications.

  • Compact size : Width of 17.5 mm
  • True RMS measurement
  • Under voltage, Over voltage protectionas well as protection against Phase unbalance, Phase failure, Incorrect phase sequence & Neutral failure
  • LED indication for faults
  • Disabling of Over & Under Voltage fault on site is possible
  • Onsite selection of VLL / VLN value based tripping
  • Self powered
  • Adjustable Nominal voltage, Trip point, Trip time delay
  • Compliance to International Safety standard IEC 61010-1-2010